UTICA BOILERS SSC Manuál

Procházejte online nebo si stáhněte Manuál pro Rozšíření napájení UTICA BOILERS SSC. Utica Boilers SSC Submittal Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 6
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
P/N 240010478 REV B, [06/2014]
Engineer:____________________________________________
Project Name:________________________________________
Project Location:______________________________________
Contractor:___________________________________________
2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com
APPLICATION:
Gas red hot water heating boiler for indoor installations. Approved for closet or alcove installations. For
use with natural or liqueed petroleum gases (LP/propane) LP conversion kit provided with the boiler. Wall
mounted, optional oor mount kit available. Constructed and hydrostatically tested for maximum allowable
working pressure of 150 PSIG (pounds per square inch gauge) in accordance with ASME boiler and pressure
vessel code, section IV, rules for construction of heating boilers.
BOILERS INCLUDE:
• Wall Mount Bracket
• Boiler Control Module
X Line voltage/intermittent direct spark ignition. Replaceable fuse /extra spare fuse shipped with the
control.
X Controlling premix modulating gas valve and blower.
X User interface with LCD screen display English text—boiler status indication.
X Function Programming Keys - Reset, Menu, Enter and arrow s (+ - ).
X Central Heating CH and Domestic Hot Water DHW setpoints. Domestic hot water priority with
programmable maximum priority time.
X Outdoor air sensor. Programmable reset curves and warm weather shutdown or xed water
temperature operation.
X Boost function temperature setting and adjustable boost time .
X Integral multiple boiler control capability up to 15 boilers. Requires an optional system sensor
X Service reminder status.
• Boiler Combustion System
X Premix Gas valve and blower assembly with 20-100% modulating ring rate. Turn down ratio (5:1) gas input.
X Stainless Steel Fiber Mesh Burner
X Flame Sensor
Zobrazit stránku 0
1 2 3 4 5 6

Shrnutí obsahu

Strany 1

P/N 240010478 REV B, [06/2014]Engineer:____________________________________________Project Name:________________________________________Project Locati

Strany 2

P/N 240010478 REV B, [06/2014]Models & CapacitiesSizeBoiler Input Rate (MBH)(1)Heating Capacity (MBH)(1)(2)Net AHRI Rating, Water (MBH)(1)(3)AFUE(

Strany 3 - Physical Data

P/N 240010478 REV B, [06/2014]2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com Physical DataModels050/075/100 150/200 299Width (A) 20"

Strany 4

P/N 240010478 REV B, [06/2014]2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.comDimension Combustible Materials (1)Service(1)(2)Model050/075

Strany 5

P/N 240010478 REV B, [06/2014]2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.comVENTINGFlue Gas Location Combustion Air Location Flue Gas Ter

Strany 6

P/N 240010478 REV B, [06/2014]2201 Dwyer Ave. Utica, NY 13501 www.UticaBoilers.com

Komentáře k této Příručce

Žádné komentáře